Load Control

A new generation of power factor enhancement and correction products.

Load Control combines multiple technologies; capacitance, which supplies the motor, the kVAR it needs to operate, Harmonics which reduce resistance, Transient Voltage Surge Suppression (TVSS) and the ability to capture, store, and reuse normally wasted power produced by the motor user friendly to 600 VAC.

• NEC-ETL/UL Certified

• Certified to ANSI/U.L./E.T.L. STD 810

• Saves From Line Side, Not Load Side

• Connects in Parallel to Load

• 5 Year Warranty & Product Liability

Benefits Include:

  • Single and three phase
  • Reduce KVAR = Improve Power Factor
  • KVA Reduction
  • Prolong equipment life
  • User Friendly to 600 VAC
  • Line Block THD

TECHNICAL DATA

Capacitors/Components:

  • Standards: IEC60831-1,2 EN60831-1,2 UL810 Latest Editions, UL/ULC File E97723
  • Overvoltage: Line rated + 10% up to 8h daily, 15% up to 30 min. daily
  • Overcorrect: 1.3 x rated, 1.5 x rated with 10% overvoltages
  • Inrush current: 300 times rated current
  • Tolerance: +/- 5%
  • Protection: Overpressure tear off fuse, self healing, discharge resistors, TVSS line to line, line to ground with filter capacitor suppression.
  • Terminal to casing insulation test voltage: 4800VAC for 2s.
  • Operating altitude: 0 to 2000 m above sea level
  • Statistical Life Expectancy: >150,000 operating hours

Other:

  • Field wires: 3, 6ft. lengths 10 to 4 AWG per model specification, plus 1, 6ft. 10AWG ground wire.
  • Conduit interface: Panel mounted 1” liquid tight compression with 3 ft. flex conduit
  • Indicator: Green, 1” round, LED
  • Warranty: 3 years

Enclosure:

  • Dimensions (Mid Size, 25 to 50kVAR): 14 x 12 x 6 in (H x W x D)
  • Dimensions (Large Size, 55 to 75kVAR): 16 x 14 x 6 in (H x W x D)
  • Construction: Hot compression molded fiberglass reinforced thermoset polyester
  • Gasket-Poured polyurethane seamless gasket provides watertight, dust-tight environmental seal
  • Color: Grey, non-conductive, UV resistant
  • Mounting-Flange, top and bottom, 2 mounting holes per side
  • Listings-UL/cUL 50/508, Types 1, 3, 4X, 6P, 12
  • UL File E64791
  • CSA Standard C22.2 File 222873
  • Types 1, 3, 4x, 6P, 12
  • NEMA Standard 250
  • Types 1, 3, 4x, 6P, 12
  • Temperature Range: -40°F to 250°F (-40°C to 120°C)
  • Flammability Rating: UL94-5V
  • Non-flame propagating

Surge protection

Protect yourself from unexpected surges and voltage spikes. Providing user and equipment safe, non‐degrading circuit isolation and surge protection for:

Benefits Include:

  • Installed as cascading primary‐to‐secondary levels, it requires no tweaking, service, or maintenance
  • Protection from ‘Electrical Pollution’ avoids degradation of sensitive PC boards and hard drives
  • Extends typical (*MTBF) life of the following electrical/electronic assets: Motors, Refrigerators and A/C’s, Lamps and Ballasts, Circuit Breakers, IC’s and Circuit Boards

Specifications:

  • For 120VAC, Single Ø – up to 480VAC 3Ø applications
  • MCOV Ratings: 130/250; 130/210; 300/510 VAC Max. (typ.)
  • Minimum Multi-Element Surge Capacity: 40,000 Amps
  • Minimum Surge Current Per Phase: 56,000 Amps
  • Rated New Total Surge Capacity: 360,000 Amps*
  • All Modes of Protection: L-L, L-N, L-G and N-G (if applies)
  • Leads are #12 Copper, Max 38” for faster response time
  • FuseLink Technology Maintains Full Rated Surge Capacity
  • UL and CUL Listed to Standard 1449, 2nd Edition
  • Easy, offset mounting using a 1/2” panel knockout
  • Safety tested to ANSI/IEEE C62.11,C62.41 & C62.45 Std. 587
  • Remote’Alert Provides Auto-remote Protection Status Alert*
  • LED Self-test Protection Status Monitors for each phase
  • Features Fiberglass NEMA Type 4X Rated Enclosures